OA-Edge T

Specifications

Model OA-Edge & OA-Edge T
Profile colour Silver / black
Mounting height 1.5 (4’11”) to 3.0 m (9’10”)
Detection method Triangulation
Detection spots OA-Edge 2 detection spots per module
Detection spots OA-Edge T 4 detection spots per module
Min. configuration 1 master module + 1 LED module
Max. configuration 4 sensor modules + 2 LED modules
Depth angle adjustment 0ºC – +25ºC
Power supply 12 – 24 VAC ±10% (50 /60 Hz) 12 – 30 VDC ±10%
Power consumption  < 1.3W ( < 2VA at AC) at min. configuration < 3.5W ( < 4.5VA at AC) at max. configuration
Test input Opto coupler 10 – 30 VDC Current / 6mA max.
Safety/Test output 1 Form C relay
Safety/Test output 2 Voltage / 42 VDC Current / 0.3mA max.(resistance load)
Output hold time Approx. 0.5 sec.
Response time  < 75m sec.
Operating temperature -20ºC – +55ºC (-4ºF – +131ºF)
Operating humidity 80%
IP rate IP54
Noise level < 70dBA
Tested in compliance with (OA-Edge T) EN ISO 13849-1:2008 EN ISO 12978:2003 +A1:2009 DIN 18650-1:2010 Chapter 5.7.4 ESPE
Category (OA-Edge T) 2 (EN ISO13849-1 : 2008)
Performance level (OA-Edge T) d (EN ISO13849-1 : 2008)
Dimensions various lengths x 44,3 x 50,7 mm (l x h x d)

Optex

info@optex.nl
+31 70 419 41 00